Product Overview
The 800KVA Dry Type Transformer is a 50Hz, 10,000V/400V Dyn11-connected voltage regulator featuring forced air cooling (AF) and anti-vibration pads, designed for high-density commercial and industrial power distribution.
Scope of Supply
Product: Cast resin type transformer
Number of phases: Three-phase
Rated power: 50KVA - 3150KVA dry type transformer
Primary voltage: 10,000V
Secondary voltage: 400V
Frequency: 50Hz
Vector Group: Dyn11
Customizable production: Available
Technical Specifications
|
Model |
SCB13-800kVA-10/0.4 |
|
Type |
Dry type Transformer |
|
Standard |
IEC60076 |
|
Rated Power |
800kVA |
|
Frequency |
50HZ |
|
Phase |
Three |
|
Cooling Type |
ANAF |
|
Primary Voltage |
10 KV |
|
Secondary Voltage |
0.4KV |
|
Winding Material |
Copper |
|
Vector Group |
Dyn11 |
|
Impedance |
4% |
|
Tap Changer |
NLTC |
|
Tapping Range |
±2*2.5% @ Primary Side |
|
No Load Loss |
1.090 KW |
|
On Load Loss |
6.260KW |

Applications
| Application | Installation Scenario | Benefits |
|---|---|---|
| Urban Substations | Indoor municipal and commercial networks. | Flame-retardant design prevents fire hazards. |
| High-Rise Buildings | Space-constrained mezzanines or basements. | No structural reinforcement needed. |
| Corrosive Environments | Coastal and chemical power systems. | Moisture and corrosion resistant. |
| Acoustic-Sensitive Zones | Laboratories and residential substations. | Low-noise operation minimizes disturbance. |
| Limited-Maintenance Areas | Data centers and subways. | Minimal maintenance reduces downtime. |
Transformer Process Flow Diagram

Transformer drawings

Technical Customization & Options
Enclosure & Cable Entry Customization: Tailored enclosure dimensions, top/bottom entry, or busbar connections fitting specific substation footprints.
Thermal Efficiency Upgrades: Custom air duct configurations and forced-air fan integration to increase continuous load capacity.
Dry-Type Insulation Enhancements: Specialized resin casting thickness and H-class insulation adjustments for high-humidity or corrosive environments.
Loss & Impedance Calibration: Customized core stacking and coil winding to align with localized grid efficiency regulations.
Smart Temperature Controller Integration: Pre-wiring and integration of RS485 PT100 temperature controllers matching client SCADA systems.
FAQ
Q: What routine factory tests are performed on the 800 kVA Dry Type Transformer before dispatch?
A: Every unit undergoes insulation resistance, voltage ratio, winding resistance, and partial discharge testing at our factory.
Q: How is the 800 kVA Dry Type Transformer secured during international ocean freight?
A: It is packed in IP23-rated seaworthy wooden cases with internal vacuum moisture-barriers and heavy-duty base tie-downs.
Q: Can the 800 kVA Dry Type Transformer handle short-term overloads?
A: Yes, when equipped with forced air cooling (AF), it can operate up to 120% rated capacity continuously.
Q: What is the standard manufacturing lead time for this specific 800 kVA unit?
A: The standard factory production cycle is 25 to 30 days from final technical drawing approval.
Q: Does the enclosure design allow for flexible high-voltage and low-voltage cable routing?
A: Yes, the enclosure features removable gland plates configured for either top or bottom cable entry.
Hot Tags: 800 kva dry type transformer, China 800 kva dry type transformer manufacturers, suppliers, factory, cast coil transformer, 50 kva dry type transformer, dry type cast resin, transformer dry, medium voltage dry type transformers, dry type pad mounted transformer