500KVA Dry Type Transformer

500KVA Dry Type Transformer

Rated power: 500KVA dry type transformer
Primary voltage: 10000V
Secondary voltage: 400V
Impedance:4%
Send Inquiry
Description

Product Overview

 

This 500kVA dry type transformer is custom-engineered for the Vietnamese power grid. The design integrates specialized winding configurations for optimized operational efficiency, digital thermal monitoring for precise temperature control, and localized dampening features for low-noise performance.

 

Application & Selection Guide

 

1. 500 kVA Dry-Type Transformer Application Scenarios & Key Advantages 

 

Target Environment / Scenario Specific Application Site Technical Features
High-Density Public Spaces Shopping malls, hospitals, schools Minimized Fire Risk: Oil-free solid insulation meets stringent indoor fire safety standards.
Space-Constrained Facilities High-rise office basements, apartment mezzanines Compact Footprint: Lightweight design allows installation in confined rooms.
Humid & Corrosive Zones Coastal underground complexes, chemical workshop auxiliaries Moisture Resistance: Sealed insulation prevents degradation from high humidity.
Noise-Sensitive Facilities R&D laboratories, biopharmaceutical buildings, hotels Acoustic Mitigation: Shock-absorbing spring pads dampen core resonance.
Restricted-Access Zones Data center server rooms, subway station control rooms Maintenance-Free: Solid-state structure eliminates routine oil testing.

 

2. Why Dry-Type Transformers Are Ideal for Indoor Use? 

 

Compared to oil-immersed transformers, the dry-type (cast resin) design offers distinct safety, environmental, and installation advantages that make it the preferred choice for indoor and sensitive environments:
 

Advantage Detailed Benefit for Indoor Use
Enhanced Fire Safety  Oil-free solid insulation is self-extinguishing and has no flammable liquid, significantly reducing fire risk and meeting stringent indoor fire safety codes (ideal for basements, high-rises). 
Environmentally Friendly  No risk of oil leaks, eliminating potential soil or groundwater contamination. Safe for use in environmentally regulated areas. 
Compact Installation  Generally lighter and more compact than oil-filled units for the same capacity, allowing for easier handling and installation in space-constrained indoor electrical rooms. 
Low Maintenance  Solid-state structure eliminates the need for regular oil quality testing, oil level checks, and oil filtration, drastically reducing routine maintenance effort and cost. 
Low Noise Level  Designed with advanced materials and damping features, it operates more quietly, making it suitable for noise-sensitive environments like hospitals, hotels, and office areas. 

 

3. Temperature Monitoring & Maintenance Approach 

 

Temperature Monitoring:This 500 kVA dry-type transformer is equipped with a digital thermal monitoring system for precise and continuous temperature control. Key aspects include:
 

Real-Time Monitoring :Sensors embedded in the windings provide continuous temperature readings, ensuring the unit operates within safe thermal limits (Class F/H insulation).

 

Alarm & Trip Functions :The system can be configured with programmable alarm and trip thresholds. If temperatures exceed preset levels, it triggers an alert or automatically shuts down the transformer to prevent insulation damage from overheating.
 

Fan Control :For units with forced air cooling (ANAF), the system can automatically control cooling fans, activating them when temperatures rise and deactivating them when temperatures drop, optimizing energy efficiency.
 

Maintenance Approach :The "maintenance-free" nature of dry-type transformers significantly simplifies upkeep:
 

Regular Visual Inspection :Periodically inspect for any unusual dust accumulation, physical damage, or signs of overheating on the enclosure and connections.
 

Clean Cooling Vents :Keep air intake and exhaust vents clear of debris to ensure proper ventilation and cooling efficiency.
 

Check Fan Operation :If equipped with fans, verify they start and stop correctly based on temperature signals during routine checks.
 

Periodic Electrical Testing:While routine oil testing is unnecessary, it is recommended to perform periodic insulation resistance and partial discharge measurements to track insulation system health.
 

4. Real-World Application Cases 

 

A Data Center Server Room 


A colocation data center needed a reliable, fire-safe power source for its server racks and cooling systems. They deployed a 500kVA dry-type transformer in a dedicated electrical room adjacent to the server hall. The solid-state, oil-free design eliminated the risk of a transformer fire affecting the critical IT load. The maintenance-free operation reduced the need for regular human intervention, aligning with the facility's high-reliability and security protocols.
 

Scope of Supply

 

Product: Cast resin type transformer

Number of phases: Three-phase

Rated Capacity: 500 kVA (Custom options available from 30 kVA to 3150 kVA upon request)

Primary voltage: 10,000V

Secondary voltage: 400V

Frequency: 50Hz

Vector Group: Dyn11

Customizable production: Available

 

Technical Specifications

 

Model

SCB10-500kVA-10/0.4

Type

Dry type Transforme

Standard

IEC60076

Rated Power

500kVA

Frequency

50HZ

Phase

Three

Cooling Type

ANAF

Primary Voltage

10 KV

Secondary Voltage

0.4KV

Winding Material

Copper

Vector Group

Dyn11

Impedance

4%

Tap Changer

NLTC

Tapping Range

±2*2.5% @ Primary Side

No Load Loss

1.16 KW

On Load Loss

4.88KW

 

Compliance & Technical Standards

 

✔ IEC 60076-11 Verification
Restricts routine partial discharge to ≤ 10 pC while ensuring compliance with Class F/H insulation thermal limits.

 

✔ ISO 9001 Audited Winding Process
Utilizes automated foil-winding equipment to ensure precise interlayer tension and eliminate internal voids.

 

✔ IP20 / IP23 Enclosure Compliance
Validated clearance design and ingress protection prevent hazardous particle intrusion in indoor substations.

 

✔ Pre-Dispatch Factory Testing
Each unit undergoes mandatory AC withstand test (28 kV / 1 min), insulation resistance measurement, and loss performance verification.

 

System Engineering Design

 

product-671-651

 

Engineering Drawings & Schematics

 

product-937-664

 

Manufacturing Process & Quality Control

 

Resin Casting Process Flow (Dry-Type Coils):

Preliminary preparation

Mold installation

Pouring operation

Curing treatment

Demoulding and trimming

 

Quality Control & Testing:

1. Clean-Room Coil Casting

Environmental particulate monitoring (< Class 100,000 cleanroom standards) mitigates micro-void encapsulation during vacuum resin injection to maintain partial discharge thresholds under ≤ 10 pC at 1.3Uₙ.

 

2. Multi-Zone Thermal Curing
Automated temperature regulation ensures uniform resin polymerization, preventing cracks and enhancing mechanical stability.

 

3. Dielectric Impulse Verification
Mandatory 28 kV AC withstand testing verifies high-voltage insulation strength before factory dispatch.

 

4. Short-Circuit Resistance Testing
Structural tolerance validation confirms that encapsulated copper coils can withstand severe grid short-circuit stresses.

product-600-800
product-600-800
product-600-800
product-600-800
product-600-800
product-600-800

FAQ

 

Q: Are type test reports available for this 500kVA transformer design?

A: Yes. The design is fully validated according to IEC 60076-11. Complete KEMA type test reports-including temperature rise, lightning impulse (BIL), and short-circuit withstand tests-are available upon request.

Q: How does the factory guarantee core laminations are protected from rust during seaside transit?

A: Cores receive a specialized multi-layer anti-corrosive marine varnish coating prior to sea-freight packaging.

Q: What heavy-duty logistics measures prevent internal structural shifting during overland delivery?

A: Transformers are secured using heavy-duty internal bracing and multi-point tie-downs within custom wood crates.

Q: Can the enclosure configuration be upgraded to withstand outdoor industrial dust environments?

A: Yes, the standard enclosure can be upgraded to IP23 or IP44 rated stainless steel structures.

 

Hot Tags: 500kva dry type transformer, China 500kva dry type transformer manufacturers, suppliers, factory, cast coil transformer, 50 kva dry type transformer, dry type cast resin, transformer dry, medium voltage dry type transformers, 33kv dry type transformer