China 225 kva transformer Manufacturers Factory Suppliers
-
500 Kva Distribution TransformerRated power: 500 kva distribution transformerread more
Primary voltage: 11000V
Secondary voltage: 400V
Impedance:4.5%
Connect groups:Dyn11 -
35kv TransformerRated power: 1.6MVA 1600kva distribution transformerread more
Primary voltage: 35000V
Secondary voltage: 10500V
Impedance: 6.5%
Connect groups:Dyn11 -
250 Kva Distribution TransformerRated power: 250 kva distribution transformerread more
Primary voltage: 11000V
Secondary voltage: 400V
Impedance:4.5%
Connect groups:Dyn11 -
200 Kva Distribution TransformerRated power: 200 kva distribution transformerread more
Primary voltage: 11000V
Secondary voltage: 400V
Impedance:4.5%
Connect groups:Dyn11 -
33kv Distribution TransformerRated power: 1.6MVA 1600kva distribution transformerread more
Primary voltage: 33000V
Secondary voltage: 400V
Impedance:6.5%
Connect groups:Dyn11 -
33 0.415 Kv TransformerRated power: 1MVA 1000kva distribution transformerread more
Primary voltage: 33000V
Secondary voltage: 415V
Impedance:6.5%
Connect groups:Dyn11 -
Photovoltaic TransformerRated power: 2500 kva Photovoltaic transformerread more
Primary voltage: 690V
Secondary voltage: 35000V
Impedance:6-8%
Connect groups:Dyn11
Frequency:50hz -
33kv TransformerRated power: 1MVA 1000kva distribution transformerread more
Primary voltage: 33000V
Secondary voltage: 415V
Impedance:6.5%
Connect groups:Dyn11
WebJan 3, 2024 · Isolation Transformer 225 kVA • Three Phase • Primary: 600 Volt • Secondary: 208Y/120 Volt. Conductor: Aluminum. • Frequency 60 Hz. Full Specification. Optional Features. Three phase...
WebJan 20, 2010 · If you want to convert the entire 200 amp 277/480 volt, 3-phase service to 120/208 volt, 3-phase, you would need a minimum of a 225 kVA transformer. However, a 150 kVA transformer...
WebOverview Transformer, Dry Type, 225 KVA, 3-Phase, 208 Delta Primary Volts - 277/480Y Secondary Volts, NEMA 3R, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz...
WebNov 4, 2009 · Retired Electrical Engineer - Power Systems. Nov 4, 2009. #2. Those values look like ones quoted by most power companies for oil-filled units. Energy efficiency laws have forced many...
WebThese Three Phase transformers offer consistent, smooth voltage transformation at 480VAC input. Transformers 15kVA and higher that meet DOE 2016 legislation will help...
WebJan 3, 2024 · Isolation Transformer: Phase: Three: Power Rating: 225 kVA: Frequency, Hz: 60: Vector Group: Delta-Wye(DYn) Primary voltage: 600 Volt: Primary Max Current,...